Preventing Conductive Anodic Filament (CAF) In PCBs
Conductive Anodic Filament, or CAF, is one of those hidden problems in a printed circuit board that can quietly build up and then suddenly cause failure in the field. It is not always visible on the surface. It forms inside the PCB, between layers, where you cannot see it. Preventing CAF in printed circuit boards is essential for long-term PCB reliability and CAF control, especially in demanding applications. For applications that need long-term reliability, this is serious.
So, what is CAF, why does it happen, and how can engineers reduce the risk
What Is CAF?
CAF is a type of internal electrical leakage in a PCB, often caused by electrochemical migration in PCBs that allows copper ions to move between conductors. It happens when tiny conductive paths form between copper features inside the board. These paths usually grow from an anode towards a cathode, along the glass fibre reinforcement inside the laminate. Over time, the path becomes conductive enough to cause shorts or intermittent faults.
In simple terms, moisture, an electrical bias, and a weak material structure can create a copper filament where none should exist. The result is unexpected current flow between nets that are supposed to be isolated. That is when strange field failures begin to show up. Reset behaviour. Sudden loss of signal integrity. Boards that work fine in the lab but fail after months in a humid environment.
The Electrochemical Process Behind CAF
CAF is a product of electrochemical migration in PCB materials. When a voltage is present between two conductors and moisture is available, copper ions can dissolve from the positive conductor and travel through the internal resin system towards the negative conductor. The glass weave inside the PCB can act like a channel or highway for that movement.
Over time, this migration forms a conductive filament. Once that filament bridges enough distance, it can create a leakage path or even a direct short. The higher the voltage difference and the more moisture present, the faster this can happen.
So the problem is not only electrical. It is electrochemical. The board is literally helping to grow its own failure point.
Practical PCB Design Tips To Reduce CAF
CAF control starts at the schematic and layout desks. Treat it like a constraint, just like creepage, impedance, or EMI. Engineers can apply these CAF mitigation techniques for PCB reliability and reduce CAF risk in PCB layout. Use these layout rules to cut CAF risk before fabrication even begins.
1. Keep Proper Conductor Spacing
Increase separation between conductors at different potentials on all layers, with extra margin on inner layers where moisture can hide in the glass weave.
Prioritise spacing between via barrels, plane cut-outs, and high-bias nets. Longer ion migration paths mean slower, or no, filament growth.
Route differential pairs and sensitive nets with guard spacing to nearby copper tied to different potentials.
2. Remove Non-Connected (Orphan) Pads On Inner Layers
Delete unused/thermal-isolation pads and any orphaned anti-pads on inner layers. These islands trap resin stress and moisture and can become CAF initiation points.
If a pad is required for drill support, replace full copper with minimal keepouts per fab guidance rather than leaving large copper islands.
3. Stagger Vias At About 45° (Stay Away from Straight-line Bridges)
When two nets with different potentials need to pass through the same area, stagger them by putting them at an angle of about 45 degrees instead of lining them up.
This prevents straight-line copper-to-copper paths from crossing the glass weave, reducing the likelihood of electrochemical migration.
4. Plan Where and How Far Apart Your Vias Will Be
Keep plenty of space between vias and traces, especially in designs that need to last a long time or operate at high voltage.
Keep opposing-polarity vias from running in long, parallel rows across the same dielectric. If they must, offset them and add spacing.
Observe a stricter drill-to-copper clearance than the absolute fab minimum in areas exposed to humidity or bias.
5. Avoid Dense Via Farms
Break up large clusters of vias (“via farms”), particularly between nets at different potentials. Dense arrays create micro-crack stress zones and capillary paths for moisture.
If high-pin-count BGAs force density, fan-out in stages, and introduce copper void channels (keepouts) to reduce continuous copper adjacency between opposite nets.
6. Use Teardrops On Pads And Vias
Add teardrops where traces meet pads/vias to smooth copper transitions and reduce resin stress during drilling and lamination.
Teardrops help prevent micro-voids and hairline cracks at junctions, the kinds of defects that can invite moisture and seed CAF.
Conclusion
CAF is not just a lab topic. It is a real failure mode that shows up in real hardware. The cause is electrochemical. The trigger is moisture and voltage. The cure is smart design, correct spacing, high-quality resin systems, and disciplined manufacturing.
For businesses that care about long-term reliability, CAF should be part of the design review checklist, not something discussed only after a failure report. PCB Power works with customers to support CAF prevention PCB through material guidance, stack-up advice, controlled drilling, and process discipline across fabrication. The goal is simple. Stable boards in the field, not stories about returns.
CAF prevention in PCB design isn’t just theory, it’s vital for PCB reliability and CAF control. With the right CAF mitigation techniques for PCB, manufacturers can ensure stability and minimize PCB CAF failure in the field.
If you are building for reliability and want fewer field failures, reach out to us and let us help you design and manufacture it right the first time.
Frequently Asked Questions
1. What Is a Conductive Anodic Filament, and Why Is It Dangerous?
Conductive Anodic Filament in PCBs is a conductive path that grows inside the PCB between copper features under electrical bias and moisture. It is dangerous because it can create leakage or hard shorts between nets that should be isolated, which can cause early board failure in the field.
2. Why Does CAF Happen In Some Boards And Not Others?
CAF is more common when the spacing between vias and traces is too tight, when drilling or lamination leaves microcracks, or when the board is exposed to humidity during use. Weak resin bonding around the glass weave makes it easier for copper ions to travel and form a filament.
3. How Can PCB Layout Help Reduce CAF Risk?
Layout teams can space high voltage nets further apart on inner layers, avoid long parallel runs of opposite potentials, and plan carefully via placement. These simple layout choices are part of PCB design tips that directly lower CAF risk over the life of the product.
4. When Should A Project Team Worry About CAF?
Anytime the PCB will face heat, moisture, voltage stress, or a long service life. So telecom gear, automotive systems, industrial controls, aerospace hardware and medical electronics should all treat CAF control as part of reliability planning, not an optional extra.
5. Who Can Help With Stack-Ups and Processes That Don't Work With CAF?
A good PCB manufacturing partner can help you choose the right laminate, manage the drilling, make sure the resin is of good quality, and plan your tests. PCB Power supports teams on CAF prevention PCB by advising on material systems and fabrication practices that improve long-term stability.